Sealer can seal or sealing film cut cut ineffective What are the reasons?

date:[2015-12-15]    Hits: If the sealer does not seal Sealing cut film or ineffective, there may be caused by the following reasons:1, sealing both ends of the blade is no voltage (sealing and cutting transformer damage or connection line open, reconnect or replace)2, the power supply voltage is too low (the input power supply voltage configuration)3, sealing time adjustment or improper relay damage (to re-adjust or replace)4, blade cut surface is not flat (the cleaning blade slot, reinstall the blade)5, the blade has been broken or bad (adjust or replace the blade)